Technical Data IconTechnical Data Icon

NDL.Q

End-caps for square tubes

SKU: 9422 Category:
To request 2D/3D drawings, click on the RED code/desc in Product Details below.
Technical Drawing

Product Details

Standard Elements Main dimensions Tube dimensions Max limit static load* Weight
Code Description B h h1 d External Thickness min-max Internal max-min [N] g
430551 NDL.Q-20×1.5-2-M6 20 34 5 M6 20 1.5-2 17-16 3000 10
430553 NDL.Q-20×1.5-2-M8 20 34 5 M8 20 1.5-2 17-16 3000 11
430555 NDL.Q-20×1.5-2-M10 20 33 10 M10 20 1.5-2 17-16 3000 16
430557 NDL.Q-20×2-M8 20 34 5 M8 20 2 16 3000 11
430561 NDL.Q-25×1-1.5-M8 25 34 5 M8 25 1-1.5 23-22 3000 17
430563 NDL.Q-25×1.5-M10 25 33 5 M10 25 1.5 22 3000 21
430565 NDL.Q-25×2-M8 25 34 5 M8 25 2 21 3000 16
430567 NDL.Q-25×2-M10 25 34 5 M10 25 2 21 3000 20
430571 NDL.Q-30×1.5-2-M8 30 34 5 M8 30 1.5-2 27-26 3000 20
430573 NDL.Q-30×1.5-2-M10 30 34 5 M10 30 1.5-2 27-26 3000 24
430575 NDL.Q-30×2.5-M10 30 33 5 M10 30 2.5 25 3000 24
430581 NDL.Q-35×1-2-M10 35 34 5 M10 35 1-2 33-31 3000 30
430583 NDL.Q-35×1.5-M12 35 34 5 M12 35 1.5 32 3000 37
430585 NDL.Q-35×1.5-2-M8 35 34 5 M8 35 1.5-2 32-31 3000 26
430587 NDL.Q-35×1.5-2-M12 35 34 5 M12 35 1.5-2 32-31 3000 36
430591 NDL.Q-40×1.5-2-M8 40 33 5 M8 40 1.5-2 37-36 3000 38
430593 NDL.Q-40×1.2-1.5-M10 40 33 5 M10 40 1.2-1.5 37.6-37 3000 42
430595 NDL.Q-40×1.5-2-M10 40 33 5 M10 40 1.5-2 37-36 3000 41
430597 NDL.Q-40×1.5-2-M12 40 33 5 M12 40 1.5-2 37-36 3000 44
430599 NDL.Q-40×1.5-2-M16 40 33 5 M16 40 1.5-2 37-36 3000 55
430601 NDL.Q-40×2-M8 40 34 5 M8 40 2 36 3000 26
430603 NDL.Q-40×3-M10 40 33 5 M10 40 3 34 3000 41
430611 NDL.Q-50×1.5-M10 50 34 5 M10 50 1.5 47 3000 42
430613 NDL.Q-50×2-M8 50 34 5 M8 50 2 46 3000 37
430615 NDL.Q-50×2-M10 50 32 5 M10 50 2 46 3000 41
430617 NDL.Q-50×2.5-M10 50 33 5 M10 50 2.5 45 3000 41
430619 NDL.Q-50×3-M12 50 34 5 M12 50 3 44 3000 50
430621 NDL.Q-60×1.5-2-M10 60 34 5 M10 60 1.5-2 57-56 3000 70
430623 NDL.Q-60×1.5-2-M12 60 34 5 M12 60 1.5-2 57-56 3000 74
* The max limit static load is the value above which the load applied to the element may cause some plastic material breakage, under particular conditions of use. Obviously, a factor that takes into consideration the importance and the safety level of the specific application must be applied to this value. The values shown in the table refer to the use of the end-cap in combination with a steel tube. The use of an aluminum tube may cause a decrease in the max limit static load equal to 25% due to possible deformations of the tube section under load.

Additional information

Colour

Black, matte finish.

Features and applications

The two end-cap parts are connected together by means of two pins which are housed in special counter-seats. A cavity inside the end-cap is provided for housing an hexagonal nut DIN 934.<BR>The assembly can be performed simply by positioning the end-cap, forcing it, inside the tube, with no need of screws or other fasteners.

Material

Polyamide (PA) based technopolymer. Resistant to solvents, oils, greases and other chemical agents.

Special executions on request

End-cap without nut.

Additional Technical Drawing